For Calls
+90 216 519 69 59
Product: KPB 900 Alternator: Kaplan Power Control System: D300
ISO 9001-2008 Generator is manufactured as ISO 9001-2008 Standards Certified
CE Genrator is certified with CE
2000/14/EC Enclosed product is tested according to EU noise legislation
Three Phase Rating, 50 Hz, PF 0,8 Noise Level 75. dBA
Standby Ratings [ESP] | Prime Rating [PRP] | ||||
Voltage | KVa | KW | KVa | KW | Amps |
400/230 | 900.00 | 720.00 | 800.00 | 640.00 | 115 2.00 |
Engine | Alternator | Control System |
Remote Radiator Cooling | Main line circuit breaker | Remote communication with modem |
Oil heater | Anti-Condensation Heater | Alarm output relays/ Charge Ammeter |
Fuel-Water Separator Filter | Over sized alternator | Automatic synchronizing |
Stand By Power
Supplying of emergency electrical power at variable load, in the event of normal utility power failure. This rating is maximum power, no overload capability is available.
Prime Power
Supplying of electrical power at variable load for an unlimited number of hours in the event of normal utility power failure. 10% over load capability is available.
Manufacturer | BAUDOUIN | ||
Model | 12M26G900/5E2 | ||
No. Of Cylinders & Build | 6 Cylinder, In Line | ||
Aspiration and Cooling | Naturally Aspirated | ||
Maximum Standby Power | 725 Kw | ||
Total Displacement | L | 31.8 | |
Bore & Stroke | mm | 150×150 | |
Compression Ratio | 15:7:1 | ||
Rated Speed [RPM] | rpm | 1500 rpm | |
Governer | Electronic | ||
Oil Capacity | L | 114 | |
Coolant Capacity | L | 90 | |
Start System | 24 V D.c. | ||
Fuel Consumption | Load | 100% | |
Load L/H | 172 |
Replacable cylinder jacket
Dry type replacable oil filter
Heat-resistant radiator for 50 °C
Make | Kaplan Power | |
Model | KPB 900 | |
Short Circuit Current | > 300% | |
Frequency | 50 Hz | |
Power | kVA | 900 |
Design | Brushless, 4 Poles | |
Phase | V | 3P |
Voltage | A | 400/230 |
Current | 1150 | |
Insulation Class | H | |
Stator | 2/3 steps | |
Rotor | Single Bearing System | |
Excitation System | Etectronic AVR() | |
Stationery Voltage Regulation | 1%(+/-) | |
Connection Type | Star |
4 Poles, Self-Excitation, Brushless, Synchrontype alternator
Electronic type automatic voltage regulator (AVR)
Self-Cooled
• Diesel and gas gensetsupport • 400Hz operation support • 400 event logs, full snapshot • All parameters front paneleditable • 3 level configuration password • 128×64 graphical LCD display • Downloadable language • GPRS • Waveform display of V & I • Harmonic analysis of V & I • Synchroscope & check synch • Allows closed transfers • 16Amp MCB & GCB outputs • 8 configurable digital outputs • Outputs expandable to 40 • 4 configurable analog inputs • Both CANBUS-J1939 & MPU • 3 configurable service alarms • Multiple nominal conditions • 4 quadrant power counters • Mains power counters • Fuel fiiling counter • Fuel consumption counter • Modem & Ethernet diagnostics • Configurable through USB,RS-485, Ethernet and GPRS | • Multiple automatic exerciser • Weekly operation schedule • Dual mutual standby withequal aging of • gensets • Manual “speed fine adjust" onselected • ECUs • Automatic fuel pump control • Disable protections feature • Excess power protection • Reverse power protection • Overload IDMT protection • oad shedding, dummy load • Multiple load management • Current unbalance protection • Voltage unbalance protection • Fuel fiiling & fuel theft alarms • Battery back-up real time clock • Idle speed control • Battery charge run enabled • Combat mode support • Allows SMS controls • Ready for central monitoring • Ethernet and GPRS • Mobile genset support • Automatic GSM geo-location • GPS connectivity ( USB & RS232 ) • Dynamic DNS support • Easy USB firmware upgrade • IP65 rating with standard gaske |
KP 900 Canopy
Sound proof auhtenticated and Weathe insulated Enclosures for generating sets from Kaplan, meet event the sound requirements and provide optimum
protection from inclement weather and development by our specialist acoustic engineers.Our modular designed sound insulated canopies provide ease of
access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset
cooling performance, providing you with confidence that genset ratings and ambient capability.
Width | mm | 2000 |
Length | mm | 5000 |
Height | mm | 2000 |
Standard Fuel Tank | L | 650 |
Dimensions & Weight | Dimensions & Weight | ||||
Length (L) | mm | 5000 | Length (L) | mm | 5000 |
Height (H) | mm | 2000 | Height (H) | mm | 1905 |
Width (W) | mm | 2000 | Width (W) | mm | 2000 |
Wet Weight | kg | 3850 | Wet Weight | kg | 3345 |
Standard Fuel Tank | L | 850 | Standard Fuel Tank | L | 845 |